Maintenance and maintenance of fan coil (1)

The author:AdminPopularity:367release time:2017-08-09
1) air filter
Air filter is used to purify the main components of the return air, usually raw materials are chemical fiber materials or multi-layer metal mesh. Because of the orientation of the fan coil device, the length of the operation time, the use of different conditions, the cleaning cycle and cleaning methods are not the same, usually in the series should be used once a month cleaning time. If the cleaning operation is not timely, the filter hole congestion is very serious, it will make the fan coil air volume greatly reduced, the room to the cold (heat) the amount will be greatly reduced accordingly, thus affecting the quality of room temperature control.
Air filter cleaning method preferred vacuum cleaner cleaning method, the method has the greatest advantage of cleaning without having to open the filter. For those who are not easy to absorb clean dust, you have to use the removal of the filter with water pressure scouring or rinsing, or washing with water cleaning method.
Note: The air filter cleaning operation is the fan coil coil maintenance operations in the most frequent, the largest amount of operations, it is necessary to give adequate attention and reasonable organization.
2) drip tray
Sheng holding condensate drip tray (also known as water tray, water tray), and discharged through the drain. The air filter of the fan coil is usually a coarse filter, and some fine dust will pass through the filter cavity and attached to the outer surface of the coil. When the surface of the coil has a condensed water, the dust will fall into the drip tray The Therefore, the drip tray is necessary to carry out regular cleaning, will be stacked in the drip tray of dust cleaning clean. Otherwise, the accumulation of dust too much, one will make the water capacity of the drip tray to reduce the amount of condensation in the condensate when the larger, because the secretion does not form a condensate from the drip tray overflow damage to the room ceiling of the event; Mouth, the occurrence of condensate water spill; three will breed bacteria, the location of the room staff poses a threat to health.
Drip tray is usually washed twice a year, if it is seasonal use of air conditioning. It is cleaned once after the air conditioning is finished. Cleaning methods are usually washed with water, the sewage discharged from the drainage pipe, but also to clean the drip tray and then disinfectant water (such as bleach) rinse again.